Autochem Ingeniious

Autochem Ingeniious is a semi automated clinical chemistry analyser & has been designed to meet the demands of the research as well as laboratory staff. Compact ergonomic design which is ideal for use in small-to-medium-sized laboratory.

Description

Autochem Ingeniious is a semi automated clinical chemistry analyser & has been designed to meet the demands of the research as well as laboratory staff. Compact ergonomic design which is ideal for use in small-to-medium-sized laboratory.

  • In-built Peltier regulated incubation compartment
  • Integrated Coagulation Testing Mode
  • Single & profile wise testing facility
  • Flexible calibration modes
  • Direct access key to run tests
  • Enhanced Patient Data Storage & Retrieval
  • Daily & monthlty QC program
  • Wash & Aspiration function can be controlled using External Keyboard (PS/2 keyboard)

Technical Specifications


OPTICAL SYSTEM / PHOTOMETER

Optical Design: Single beam with rotating filter wheel
Measurement Mode: Monochromatic & Bichromatic
Light Source: Quartz Halogen Lamp, 12 V, 20 W
Photometric Range: -0.005 – 2.5 Absorbance
Standard wavelengths: 340, 405, 510, 546, 578, 630 nm + Two optional
Filter Type: 4-Cavity interference, long life ion beam assisted deposition
Wavelength accuracy: +/- 5nm
Sample Holder: 18 µL flow cell, 10 mm square/semi-micro cuvette, Coagulation adaptor and cuvette


DATA PROCESSING

Calculation Modes

  • Absorbance

  • End Point (with & without sample blank)

  • Kinetic (with and without Reagent Blanking)

  • Fixed Time (with and without Reagent Blanking)

  • 1-Point with Sample Blank

  • Coagulation

  • Profile (up to 8 tests/profile)

Calibration

  • Factor mode

  • Single-standard mode

  • Multi-standard mode (up to 6 standard) (spline)

  • Multi-standard mode (up to 6 standard) (point to point)

Data storage capacity

  • 144 test parameters

  • 24 profiles

  • 2000 (latest) samples, 200 calibrators/standards, 576 daily controls

  • 10 (latest) graphs

Result retrieval: Patient ID wise, Test wise, Date wise


TEMPERATURE CONTROL

Cuvette temperature: Peltier based
Operating temperature: 30 & 37 °C (+/- 0.2 °C)
Incubation block: Inbuilt for 37°C ± 0.2°C

  • 16 places for 12 mm diameter test tubes


FLUIDIC SYSTEM

Flow cell volume: 18 µL
Aspiration volume: 200 µL – 2000 µL
Aspiration: Stepper driven peristaltic pump

Data Management

  • Display type: 240 x 128 resolution graphical LCD with backlight

  • Data input: In-built 28 keys membrane keypad

  • Facility to connect to external standard computer keyboard

  • Real time curve plotting of absorbance Vs. Time

  • Internal thermal printer (speed up to 0.5 lines/second)

  • Facility to connect to external 80 column dot matrix printer

  • Serial port for computer connectivity


POWER / DIMENSIONS

Power requirements: Input Voltage : 90-260 VAC, 50/60 Hz
Power Consumption: 100 Watts Max
Operating Environment: 20°C to 40°C, RH: 85% max
Relative Humidity: 10% to 85%, Non-condensing
Dimensions: 35 cm (W) x 34 cm (D) x 26 cm (H)
Weight: < 10 kg

In-built Peltier regulated incubation compartment

Cost Efficient

  • Saves cost of buying additional Incubator (approx. Rs.5000)

  • Saves space of approx. 1 Sq. Feet for placing the additional incubator

Flexible

  • On/Off facility for using incubator when required

Convenient

  • Integrated timer with buzzer for ensuring right incubation time


Integrated Coagulation Testing Mode

Cost Efficient

  • Saves cost of buying additional Coagulation Analyser (approx. Rs.75,000)

  • Saves space of approx. 1 Sq. Feet for placing the additional incubator

  • No manual calculation of INR

Convenient

  • No maintenance of additional coagulation instrument & accessories

(Image: Special Coagulation Cuvette, Coagulation Cuvette Holder)


Single & Profile Wise Testing Facility

Program to create 24 different profiles / panels & upto 8 different tests in each profile

  • Convenience of running multiple parameters on same sample without switching program

  • Enables faster sample turn around


Flexible Calibration Modes

Single & Multi-Point Calibration Possible

  • Flexibility to run routine as well as specialized parameters (Eg. Immunoturbidimetry) on same instrument

Auto-normalization of Calibration curve making recalibration simple & cost effective

  • Recalibration can be done using any 1 Standard and the instrument will automatically normalize the calibration curve

  • Save cost of expensive reagents and standards


Easy Operation

  1. Wash & Aspiration function can be controlled using External Keyboard (optional PS/2 keyboard)

  2. Direct access key to run tests

    • Saves time by directly running 9 program tests with single key from main menu, without accessing detailed test menu

    • Reduces chance of error by eliminating the need to memorize test menu number


Enhanced Data Management Capability

Enhanced Patient Data Storage & Retrieval

  • Stores data of latest 2000 samples, 200 calibrators/standards, 576 daily controls and 10 reaction graphs

  • Flexibility to retrieve Sample & Calibration results by – Patient ID, Date & Test Name

  • Facility to input patient information & demographic details

Daily & monthly QC program

  • Manage 2 levels of controls with Levey-Jennings Chart

Reviews

There are no reviews yet.

Be the first to review “Autochem Ingeniious”