Description
Quality That Counts
Trust your results—the first time—with high-quality hematology analyzers that deliver precise, accurate results and advanced cellular insights.
- Achieve superior RBC, PLT and WBC differentials through near native-state cellular characterization
- Deliver high-confidence results on the first run—minimizing reruns and reflex tests
- Improve slide interpretation with intelligent technology that helps optimize smearing, ensuring consistent slide quality
Productivity That Liberates
Free up your busy laboratory’s hematology team and empower your staff to focus on samples and tasks that truly need attention
- Simplify workload planning with predictable hematology workflows that let you save time for the unexpected
- Optimize your limited resources with reliable flagging
Savings That Empower
Tap into powerful savings to help your lab devote time, budget, and resources where they are needed most
- Streamline QA/QC processes through customizable, automated technology with daily reminders and remote support
- Save time, reduce costs, and optimize hematology instrument usage with fewer reflex tests
o Reduce hematology reagent use and associated costs
o Reallocate up to 200 minutes of daily run-time previously spent on reflex testing1
o Reduce overhead costs like electricity and maintenanceTechnical Specifications
Methodology
Enhanced Coulter Principle, VCS 360 with DataFusion Parameters
CBC: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, RDW-SD, PLT, MPV Differential: NE, LY, MO, EO, BA, NRBC, NE#, LY#, MO#, EO#, BA#, NRBC #, MDW (when enabled)
Retic: RET, RET#, MRV, IRF
Body Fluids (Cerebrospinal, Serous, or Synovial): RBC, TNC
Throughput (tests per hour)
Up to 100 samples/hour Sample Volumes
165 μL aspiration volume; 0.5 ml dead volume. Predilute: 50 μL whole blood into 200 μL of diluent Analytical Measuring Ranges2
Whole Blood (CBC) Parameters Units Analytical Measuring Range WBC x103 cells/μL 0.050–400.000 RBC x106 cells/μL 0.005–8.500 HGB g/dL 0.10–25.50 MCV fL 50.00–150.00 RDW % 10.00–40.00 RDW-SD fL 15.00–150.00 PLT x103 cells/μL 3.0–3000.0 MPV fL 5.00–25.00 Body Fluids TNC cells/mm3 20–89,000 RBC cells/mm3 1,000–6,200,000 Data Management
Up to 50,000 patient results with histograms, scatter plots, and demographics 100,000 patient results with graphics for power computer
Quality Assurance
QC with Levy-Jennings graph; XB/XM for moving averages, daily check, intelligent quality monitoring, MRV, IRF, customizable calibration and QC reminders and alerts, auto export of QC Acoustic Noise Level
≤ 60 dBa Radio Frequency and Interference Immunity
Meet the product level standards EN 61326-1 (Electrical Equipment for Measurement, Control, and Laboratory Use—EMC Requirements), and EN 61326-2-6 (Part 2, Specific Requirements for In-Vitro Diagnostic Devices) Power Consumption
DxH 900 SPM: 520 W (1775 BTU/hour), Monitor: 35 W (120 BTU/hour), DxH Power Computer: 160 W (546 BTU/hour) Dimensions and weight3
Width Height Depth Weight 76.2 cm (30 in.) 176.53 cm (69.5 in.), with cover closed 199.39 cm (78.5 in.), with cover open
83.82 cm (33 in.), including the removable back panel 80 cm (31.5 in.), excluding the removable back panel
~292.11 kg (644 lbs.),
including monitor & computer~287.12 kg (633 lbs.),
excluding computerAdditional Clearance
15.2 cm (6.0 in.) per side of instrument for troubleshooting; 3.8 cm (1.5 in.) behind instrument for sufficient cooling Maintenance and Troubleshooting
Service
New Preventative Maintenance (PM) schedule with customer care visits Support
Onboard IFU and Instructional Videos, Automated QC and calibration reminders, PROService Analyzer Downtime
Minimum of 30 minutes in cleaner every 24 hours with automatic daily checks Research Use Only Parameters
Available RUO Parameters4
BFM, BFM#, BFP, EGC, EGC#, HLR, HLR#, LHD, MAF, MSCV, PCT, PDW, RDWR, RDWR-SD, RSF, UGC, UGC#, UWROP, WDOP, WNOP, WROP, CPD (refer to reference 4 for additional RUO parameters) Research Use Only. Not for use in In Vitro Diagnostic procedures.
2. DxH 900 IFU (PN C06947.AD)
3. DxH 900 ReadMe (PN C53971.AB)
4. DxH 900 RUO AddendumInstructions for Use – UniCel DxH 900 Series with System Manager Software Coulter Cellular Analysis System; Published Version: DxH 900, DxH Slidemaker Stainer II, and DxH 690TInstrument IFU – Instrument IFU/Manual Lot No / Serial No: N/A Languages: English Line / Series / ProductUniCel DxH 690T Coulter Cellular Analysis System, UniCel DxH Slidemaker Stainer II Coulter Cellular Analysis System, UniCel DxH 900 Coulter Cellular Analysis SystemItem / Ref No.C06947Document No.C06947.AEReleased Date2/14/2025Instructions for Use – UniCel DxH 900 Series with System Manager Software Coulter Cellular Analysis System; Published Version: DxH 900, DxH Slidemaker Stainer II, and DxH 690TInstrument IFU – System Help Lot No / Serial No: N/A Languages: English Line / Series / ProductUniCel DxH 690T Coulter Cellular Analysis System, UniCel DxH Slidemaker Stainer II Coulter Cellular Analysis System, UniCel DxH 900 Coulter Cellular Analysis SystemItem / Ref No.C06947Document No.C06947.AEReleased Date2/14/2025RUO Addendum – UniCel DxH 900 Series with System Manager Software Coulter Cellular Analysis System; Published Version: DxH 900 and DxH 690T – v2Instrument IFU – IFU/Manual Addendum Lot No / Serial No: N/A Languages: English Line / Series / ProductUniCel DxH 690T Coulter Cellular Analysis System, UniCel DxH Slidemaker Stainer II Coulter Cellular Analysis System, UniCel DxH 900 Coulter Cellular Analysis SystemItem / Ref No.C11340Document No.C11340.ACReleased Date2/14/2025Installation, Operation, and Performance Qualification – UniCel DxH 900 Series with System Manager Software Coulter Cellular Analysis System; Published Version: DxH 900, DxH Slidemaker Stainer II, and DxH 690T – v2Instrument IFU – Instrument IFU/Manual Lot No / Serial No: N/A Languages: English Line / Series / ProductUniCel DxH 690T Coulter Cellular Analysis System, UniCel DxH Slidemaker Stainer II Coulter Cellular Analysis System, UniCel DxH 900 Coulter Cellular Analysis SystemItem / Ref No.C11346Document No.C11346.ACReleased Date2/14/2025Host Transmission Manual – Early Sepsis Indicator (ESId) Application for UniCel DxH 900 Series with System Manager Software Coulter Cellular Analysis Systems; Published Version: DxH 900, DxH Slidemaker Stainer II, and DxH 690T – v1Instrument IFU – Host Transmission Specifications Lot No / Serial No: N/A Languages: English Line / Series / ProductUniCel DxH 690T Coulter Cellular Analysis System, UniCel DxH Slidemaker Stainer II Coulter Cellular Analysis System, UniCel DxH 900 Coulter Cellular Analysis SystemItem / Ref No.C26693Document No.C26693.ACReleased Date4/28/2020Tips & Tools
Select Tips & Tools to access helpful documents and information for your instrument.
Step 1: To access content such as job aids, checklists, In-Lab Training Manuals, etc., select the Tips & Tools link in the top left navigation.
Step 2: Select the product name.
Step 3: You will be directed to the product page and access to the product-specific content.
Tips & Tools
- DxH 520 Implementation Workbook
- DxH 520 Instrument Maintenance Checklist
- Hematology Performance Verification Guide
- Unicel DxH Series 600 & 800 Competency Checklist
- Unicel DxH Series Cleaning Checklist
- DxH New Features
- DXH Series Competency Checklist
- Unicel DxH Workcell Settings
- BD MAP Tubes Tech Tips
- Loading Diluent in the Wrong Position
- Tech Tip DxH LIN-X Using the Studies Mode
- Tech Tip DxH LIN-X
- Tech Tip UniCel DxH Downtime Procedure
- UniCel DxH Connectivity Settings