Description

    • Cardiac
      BNP

      Helping evaluate the severity of heart disease, including congestive heart failure (CHF)

      The BNP test the level of BNP in the blood to help assess the severity of heart diseases, including congestive heart failure (CHF).

      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma
      Reaction Time
      12 mins
      Detection Range
      AFIAS (5 – 5000 pg/ml)
      ichroma™ (5 – 5000 pg/ml)
      Indication
      Acute Heart failure, Congestive Heart Failure

       

      Cardiac Triple

      Simultaneous testing for Tn-I, CK-MB, and Myoglobin

      Tn-I, CK-MB, and Myoglobin are secreted in blood after the heart gets injured by cardiac stress for the lack of oxygen. The levels of these biomarkers can reveal the degree of a heart attack or damage. It would test for the level of those biomarkers in the blood to assist clinicians to assess the cardiac health status.

      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      12 mins
      Detection Range
      AFIAS (Tn-I 0.01 – 15 ng/ml, CK-MB 3 – 100 ng/mL, Myoglobin 5 – 500)
      ichroma™ (Tn-I 0.01 – 15 ng/ml, CK-MB 3 – 100 ng/mL, Myoglobin 5 – 500)
      Indication
      Acute myocardial infarction, Acute coronary syndrome

       

      Creatine Kinase Muscle Brain (CK-MB)

      Assessing to diagnose myocardial infarction in 12-48 hours

      The appearance of elevated CK-MB levels in serum is highly specific and sensitive for myocardial cell wall injury. Since it varies from one to another, other biomarkers such as Troponin I should be considered together with the CK-MB test to assess heart health. It provides solution to measure blood CK-MB level on a POC level.

      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      12 mins
      Detection Range
      AFIAS (3 – 100 ng/ml)
      ichroma™ (3 – 100 ng/ml)
      Indication
      (Acute)myocardial infarction, Primary Coronary Syndrome

       

      D-Dimer

      Measuring D-dimer level in 12 mins

      The presence of D-dimer in blood indicates that thrombin has been formed and fibrin generated from fibrinogen in vivo as a result of activation of the coagulation system. This test measures the level in the blood to help assess the thrombotic state.

      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma
      Reaction Time
      12 mins
      Detection Range
      AFIAS (50 – 10,000 ng/ml)
      ichroma™ (50 – 10,000 ng/ml)
      Indication
      Deep Vein Thrombosis, Diffuse or disseminated intravascular coagulation, Various embolisms including PE and strokes

       

      hsCRP

      Helping prognosis the occurrence of heart disease, cardiovascular disease, and stroke

      hsCRP is a test for testing the low level of CRP. Significantly high CRP levels are most likely a sign of a serious underlying medical condition. The most common cause is a severe infection, but there are other specific causes leading to a high CRP level. This test measures the level of CRP in 3 minutes.

      Diagnosis diseases
      Acute coronary syndrome, Stroke. Peripheral artery disease, Myocadiac infarction
      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      3 mins
      Detection Range
      ichroma™ (0.1 – 10 mg/L)
      Indication
      Acute coronary syndrome, Stroke. Peripheral artery disease, Myocadiac infarction

    • LDL-Cholesterol Direct

      Early detection of cardiovascular disease risk & monitoring of cholesterol levels

      LDL-cholesterol Direct testing measures the amount of LDL cholesterol in a sample of blood directly using sandwich immunodetection method. LDL cholesterol is known as a type of “bad” cholesterol because it can build up in the blood vessels such as arteries and increase the risk of stroke, heart disease, and heart attack. Accessing LDL cholesterol levels can be involved in screening of cardiovascular disease risk, monitoring to assess cardiovascular health and to see if treatment to lower LDL cholesterol has been effective.

      Diagnosis diseases
      Risk factors of cardiovascular disease & cholesterol levels
      Available Instruments
      ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      Serum/Plasma
      Reaction Time
      10 mins
      Detection Range
      Quantitative Outputs
      Indication
      Cardiovascular disease

       

      Myoglobin

      Assessing to diagnose acute myocardial infarction and help appropriate treatment

      Measurement of myoglobin provides an early index of damage to the myocardium, such as occurs in myocardial infarction (MI) or reinfarction. Increased levels, which indicate cardiac muscle injury or death, occur in about 3 hours. Two negative results from consecutive Myoglobin tests eliminate the MI from consideration.

      Diagnosis diseases
      Myocardial Infarction (MI)
      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      12 mins
      Detection Range
      AFIAS (2 – 500 ng/ml)
      ichroma™ (5 – 500 ng/ml)
      Indication
      Acute myocardial infarction (AMI)

       

      NT-proBNP

      Helping to diagnose heart diseases and evaluate the severity level

      BNP and NTproBNP are peptides that are continuously produced in the heart. When the muscles in the left ventricle over-stretch as in heart failure, the secretion of these peptides into blood increases. One may utilize the level of NTproBNP in blood to assess the cardiac event and its severity. Both of BNP and NTproBNP can be used to show different aspects of the heart failure.

      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      12 mins
      Detection Range
      AFIAS (10-30,000 pg/ml)
      ichroma™ (10-30,000 pg/ml)
      Indication
      Exclusion test for heart failure diagnosis

       

      ST2

      Measuring the level of ST2 in blood for prognosis of heart failure

      ST2 signals the presence and severity of adverse cardiac remodeling and tissue fibrosis, which occurs in response to myocardial infarction, acute coronary syndrome, or worsening heart failure. This test provides prognostic information, which is independent of other biomarkers used to probe the cardiac event.

      Available Instruments
      AFIAS-1AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      12 mins
      Detection Range
      AFIAS (3.1 – 200 ng/ml)
      ichroma™ (3.1 – 200 ng/ml)
      Indication
      Heart failure, Severity of the HF
      Troponin I (Tn-I)

      Monitoring Troponin I to screen myocardial infarction for urgent

      Troponin I (Tn-I) can diagnose myocardial infarction and myocardial necrosis at an early stage by accessing Tn-I level in the blood, thus can help prevent progression to more severe cases.

      Diagnosis diseases
      Myocardial Infarction (MI)
      Available Instruments
      ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      plasma, serum
      Reaction Time
      12 mins
      Detection Range
      ichroma™ (0.1 – 50 ng/ml)
      Indication
      Acute myocardial infarction, acute coronary syndrome

       

      Troponin I (Tn-I) Plus

      Early diagnosis of myocardial infarction with high sensitivity

      Early diagnosis of myocardial infarction with high sensitivity

      Troponin I (Tn-I) Plus can diagnose myocardial infarction and myocardial necrosis at an early stage with high sensitivity by accessing Tn-I level in the blood, thus can help prevent progression to more severe cases.

      Diagnosis diseases
      Myocardial Infarction (MI)

      Available Instruments
      AFIAS-1AFIAS-3AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      12 mins
      Detection Range
      AFIAS (0.01 – 15 ng/ml)
      ichroma™ (0.01 – 15 ng/ml)
      Indication
      Acute myocardial infarction, acute

       

      Troponin T(Tn-T)

      Assessing myocardial infarction by monitoring Troponin T

      Troponin T is a member of the troponin complex, proteins involved in the contraction of skeletal and heart muscles. It is known as an excellent biomarker to estimate myocardial damage. The Troponin-T test can provide the quantitative result in 12 minutes with fingertip blood.

      Diagnosis diseases
      Myocardial Infarction (MI)

      Available Instruments
      AFIAS-1AFIAS-6AFIAS-10ichroma™ IIichroma™ III
      About Using Reagent
      Sample Types
      whole blood, plasma, serum
      Reaction Time
      12 mins
      Detection Range
      AFIAS (10 – 20,000 pg/ml)
      ichroma™ (10 – 20,000 pg/ml)
      Indication
      Acute Myocardial Infarction, Acute Coronary Syndrome

Reviews

There are no reviews yet.

Be the first to review “Reagents(Boditech) – Cardiac”

Your email address will not be published. Required fields are marked *