•SMART MAINTENANCE
•SMART LIS
•SMART INVENTORY MANAGEMENT
REDUCED ERRORS:
IT allows for the accurate collection of data, automated workflows &
minimized waste.
SAVES TIME:
Patient monitoring can be done in real-time, saves engineers visiting time.
BETTER PATIENT EXPERIENCE:
A connected laboratory system creates an environment that meets each patient’s needs.
INSTRUMENT BREAKDOWN MANAGEMENT:
Real-time data helps to monitor instrument performance.
ONLINE REACTION CURVES:
• Real time reaction curve with special
• Flagging gives confidence in patient reports.
INTELLECTUAL SOFTWARE:
• User friendly Device.
• 150 Direct access test keys gives freedom
to select parameters easily.
• Availability of different assay modes.
DRY BATH INCUBATOR:
• Dry bath incubator with 12 test tube positions
• Mini size with 15 minutes start up time
Direction For Use :
Please ensure that the power source is properly grounded and voltage between Line
and Ground is less than 2V AC – 5V AC.
• Please ensure that the instrument is placed on a firm table, clean environment, and
sufficient ventilation space.
• Switch On the instrument.
• Instrument will run its own internal diagnostic routines, to ensure proper working of
critical functions.
• Allow the instrument to stabilize for 10 minutes.
• During the stabilization time, please wash the flow cell with cleaning solution and
distilled water for at least two times.
• During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution
and rinsed thoroughly using distilled water.
• For overnight shutdown, please ensure flow cell is filled with distilled water.
• Cover the instrument with the given dust cover
Precautions :
• Instrument should be operated only by authorised or trained personnel
• For any reasons, unauthorised personnel should not be engaged for servicing or
removing the cabinet
• Power source should be regulated either by voltage stabilizer or regulated power
back up (UPS). If inverter is been used, please ensure there exists a voltage stabilizer
• Reagents recommended by the company to be preferably used
• Flow cell needs to be rinsed regularly with the company recommended flow cell
cleaning solution
• User is requested not to use any other pointing devices other than being supplied by
company while operating touch screen
• The operating environment should be clean and protected from direct sunlight
• During the day at the end of the work, it should be ensured that flow cell is always
filled with distilled water
• During transport / longer duration of shut down