Thrombostat

The Thrombostat is a Single Channel Automatated Coagulation Analyser. It is up-to date, processor controlled semiautomatic measuring instruments for in – vitro diagnostic blood coagulation analysis. Its compact design and simple handling makes the THROMBOSTAT a powerful coagulometer.

Description

The Thrombostat is a Single Channel Automatated Coagulation Analyser. It is up-to date, processor controlled semiautomatic measuring instruments for in – vitro diagnostic blood coagulation analysis. Its compact design and simple handling makes the THROMBOSTAT a powerful coagulometer.

  • Features:

    ● Open system
    ● Easy to use
    ● Mechanical measuring system
    ● Designed for both Laboratory & Mobile use
    ● Can determine all coagulation parameters
    ● Maintenance free


    The principle is simple

    Starting
    When switched on, the Thrombostat automatically checks all important functions.

    Incubating
    The measuring cuvette, with the sample or reagent, is placed into one of the incubation positions.

    Measuring
    Upon completion of incubation, the cuvette is placed in the measuring channel. The measurement is then started by using either a special Start-pipette or by using the countdown timer in connection with any commercial pipette. Upon completion of the measurement, the results are automatically calculated and displayed.


    Effective in practice

    The mechanical measuring system
    A sensor monitors the ball rotating on the bottom of the cuvette.

    Three parameters leads to the positive detection of a developing coagulum:
    ● A large coagulum is created which stops the ball on the wall of the cuvette.
    ● A softer, slower coagulum build-up directs the ball towards the center of the cuvette.
    ● A change in the sample’s viscosity causes a delay in the ball’s movement.


    The Thrombostat at a glance

    Specifications Thrombostat 1
    Measuring Channel 1
    Test PT, APTT, TT
    Sample Type Whole Blood, Plasma, Capillary citrated blood
    Reagent Position 5
    Measuring Volume 150–400 µl
    Value Output INR or Seconds
    All standard reagents
    Error Control Output of error criteria
    Dimension (W x H x L) 113 x 68 x 207 mm
    Weight 1.1 kg
    Operating Voltage 115/230 V, 50-60 Hz
    Power consumption 16 VA
    Shipment Includes Main cable, ball dispenser, dust cover

    Comprehensive range of High Quality Hemostasis Reagents are also Available